BWRNV - 236B4129, BAR RUST 236 MULTI-PURPOSE EPOXY (SUPDAT)

  • MSDS: BWRNV
  • Manufacturer: DEVOE COATINGS CO
  • Product Name: 236B4129, BAR RUST 236 MULTI-PURPOSE EPOXY (SUPDAT)
  • National Stock Number: 8010-00N056241
Product Identification

Product ID:236B4129, BAR RUST 236 MULTI-PURPOSE EPOXY (SUPDAT)
MSDS Date:09/23/1993
FSC:8010
NIIN:00N056241
MSDS Number: BWRNV

Responsible Party
DEVOE COATINGS CO
4000 DUPONT CIRCLE
LOUISVILLE, KY 40207
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 502-897-9861

Cage: 1HK86

Contractor
DEVOE COATINGS CO
7600 LOUISVILLE, KY 40207-4802 US

Telephone: 502-897-9861

Cage: 1HK86

Ingredients

SILICA, CRYSTALLINE - QUARTZ

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: 20%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST


>5000 MG/KG

CAS: 25068-38-6

RTECS: KC2100000

Fraction By Weight: 30%

OSHA PEL N/K

ACGIH TLV: N/K


SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (HIGH FLASH

CAS: 64742-95-6

RTECS: WF3400000

Fraction By Weight: 10%

OSHA PEL N/K

ACGIH TLV: N/K


TALC (POWDER), CONTAINING NO ASBESTOS POWDER; (MAGNESIUM

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 20%

OSHA PEL 2 MG/M3 RESP (MFR)

ACGIH TLV: 2 MG/M3 RESP (MFR)


SILICATE, MICA; (MICA)

CAS: 12001-26-2

RTECS: VV8760000

Fraction By Weight: 5%

OSHA PEL 20 MPPCF

ACGIH TLV: 3 MG/M3 RDUST


1.2

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: <5%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


>24000

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


225.39 (GRAMS/LITER)

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


IMMEDIATELY APPARENT. OBTAIN MEDICAL ATTENTION.

RTECS: 9999999ZZ


ANTICIPATED TO BE CARCINOGEN.

RTECS: 9999999ZZ


DO NOT INDUCE VOMIT. ASPIR OF VOMIT CAN

RTECS: 9999999ZZ


MISUSE BY DELIBERATELY CONCENTRATING AND INHALING

RTECS: 9999999ZZ


CLOSED CONTAINER UNTIL PROPERLY DISPOSED OF.

RTECS: 9999999ZZ


COMPONENT PROD, THEN MIX OF BASE & CONVERTER

RTECS: 9999999ZZ


APPLICABLE PRECAUTIONS. DO NOT GET ON SKIN OR IN

RTECS: 9999999ZZ


USED IN RESTRICTED VENT AREAS, WEAR NIOSH/MSHA

RTECS: 9999999ZZ


OF PARTICULATES & VAP. WHEN USED IN CONFINED AREAS,

RTECS: 9999999ZZ


USE NIOSH/MSHA APPRVD RESP WHEN FLAME CUTTING,

RTECS: 9999999ZZ


STANDARDS IN MIXING, APPLICATN & CURING AREAS & TO

RTECS: 9999999ZZ


DURING WELDING & FLAME CUTTING ON SURFS COATED

RTECS: 9999999ZZ


REMOVING HEAVY SOLVENT VAPS FROM LOWER LEVELS OF THE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:IRRIT OF RESP TRACT; HDCH,
NAUS, DIZZ, WEAK & FATG. EXTREME EXPOS CAN RSLT IN UNCON & EVEN
RESP ARREST. SKIN/EYE:CAUSES IRRIT. MAY BE HARMFUL IF ABSORBED THRU
SKIN. INGEST:CAN CAUSE STOM &/OR INTESTINAL IRRIT, NAUS, VOMIT &
DIARR. CHRONIC:RPTS HAVE ASSOC RPTD & PRLNGD OCCUP OVEREXP TO (EFTS
OF OVEREXPOS)
Explanation of Carcinogenicity:SILICA, DRYSTALLINE-QUARTZ:IARC
MONOGRAPHS, SUPP. VOL 7, PG 341, 1987:GROUP 2A. NTP 7TH ANNUAL RPT
ON CARCINS (ING 10)
Effects of Overexposure:HLTH HAZS:SOLVENTS WITH PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE. PROLONGED OR REPEATED BREATHING OF SPRAY
MIST AND/OR SANDING DUST OVER A PERIOD OF YEARS MAY CAUSE DUST
DISEASE OF THE LUNGS.
Medical Cond Aggravated by Exposure:NONE, WHEN USED IN ACCORDANCE WITH
SAFE HANDLING AND USE INFORMATION.

First Aid

First Aid:INHAL:IF DFCLTY BRTHG, LEAVE AREA TO OBTAIN FRESH AIR. IF
CONTINUED DFCLTY IS EXPER, SUMMON MED ASSISTANCE IMMMED. IF BRTHG
CEASES, RESTORE USING APPRVD CPR TECHNIQUES & SUMMON MED HELP
IMMED. EYES:FL USH IMMED W/LG AMTS OF WATER FOR AT LST15 MIN. GET
MED ASSISTANCE. SKIN:WASH AFFECTED AREAS W/SOAP & WATER. REMOVE
SOILED CLTHG. GET MED ASSISTANCE IF IRRIT PERSISTS. INGEST:CONSULT
MD IMMED.(ING 11)

Fire Fighting

Flash Point Method:SCC
Flash Point:100F,38C
Lower Limits:1.0%
Extinguishing Media:USE CO*2, DRY CHEM, FOAM/OTHER NATIONAL FIRE PROT
ASSOC (NFPA) APPRVD METH FOR TREATING CLASS B FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ PREF. IF
EXPOSED TO FIRE/EXTREME HEAT, (SUP DAT)
Unusual Fire/Explosion Hazard:KEEP DNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & FLAME. DUE TO PRESS BUILD-UP, CLSD CNTNRS
EXPOSED TO EXTREME HEAT MAY EXPLODE. NEVER (SUP DAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT (FLAMES, HOT SURFS
& ELEC, STATIC/FRICTIONAL SPKS). PVNT BRTHG OF VAPS. VENT AREA.
BEFORE ATTEMTING CLEAN-UP, REFER TO HAZ CAUTN INFO IN MSDS. CNTN
SPILLED MATL & REMOVE W/ INERT ABOSRB & NON-SPKG TOOLS. STORE
IN(ING 13)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPKS & FLAMES. DO
NOT SMK. PVNT BUILD-UP OF VAPS BY MAINTAINING CONTINUOUS FLOW OF
FRESH AIR.
Other Precautions:DO NOT STORE >120F/NEAR FIRE/OPEN FLAME. STORE LG
QTYS IN BLDGS TO COMPLY W/OSHA 1910.106. KEEP CNTNRS CLSD WHEN NOT
IN USE. DO NOT TRANSFER CONTENTS TO BOTTLES/OTHER UNLBLD CNTNRS. DO
NOT REUSE EMPTY CNTNRS. IF MATL IS PART OF TWO (ING 14)

Exposure Controls

Respiratory Protection:DO NOT BRTHE VAPS, SPRAY MIST/SANDING DUST. WHEN
SPRAY APPLIED IN OUTDOOR/OPEN AREAS, & DURING SANDING/GRINDING
OPERATIONS, USE NIOSH/MSHA APPRVD MECH FILTER RESP TO REMOVE SOLID
AIRBORNE PARTICLES OF OVERSPRAY & SANDING DUST. WHEN (ING 16)
Ventilation:PROVIDE GEN DILUTION/LOC EXHST VENT IN VOL & PATTERN TO
KEEP AIR CONTAM CONC BELOW CURRENT APPLIC SFTY & HLTH (ING 19)
Protective Gloves:SOLV IMPERMEABLE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:SOLVENT IMPERMEABLE CLOTHING & BOOTS TO
PREVENT SKIN CONT ARE RECOM. ANSI APPRVD EYE WASH AND DELUGE SHOWER
.
Work Hygienic Practices:REMOVE AND WASH SOILED CLOTHING BEFORE REUSE.
WASH HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
MFR TRADE/PART#:COATING LIGHT BLUE BASE. FIRE FIGHT PROC:WATER SHOULD
BE USED TO COOL CLSD CNTNRS & PVNT PRESS BUILD UP/POSS AUTO-IGNIT.
EXPLO HAZS:USE WELDING/CUTTING TORCH ON/NEAR CNTNR (EVEN EMPTY) AS
PROD/ITS RESIDUE MAY IGNITE. DURINGEMER CNDTNS OVEREXP TO DECOMP
PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE (ING 9)

Chemical Properties

Boiling Pt:B.P. Text:>244F,>118C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.59
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:26.26

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CARBON MONOXIDE, CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.